GROUND TEST SWITCH (two-position, spring-loaded to center)
GND TEST - test the Flight Data Recorder (FDR) while the airplane is on the ground
- the RED-OFF-WHITE A/COL switch on the Exterior Lights Panel is set to OFF for the
test
- this causes the FLT DATA RECORDER caution light to turn on
- the test is satisfactory when the FLT DATA RECORDER caution light goes out
ELT REMOTE SWITCH (three-position, spring-loaded away from RESET)
ON - manually activates the ELT in the event of an emergency
- the ON selection overrides the automatic inertia switch
- the monitor light located within the remote switch comes on
- also provides a means to test the ELT during a preflight test
- returning the remote switch to the AUTO position terminates ELT operation, and the monitor light goes off
AUTO - operates in the automatic mode
- the ELT transmits when the inertia switch activates, and the red ELT monitor light
located in the remote switch comes on
- it is activated by longitudinal inertia forces between 5 and 7 G (gravity) acceleration
RESET - allows for reset of an inadvertent ELT activation