IGNITION CONTROL Switch ( two-position )

- controls ignition for related engine
OFF - the FADEC disables ignition regardless of ground or flight status
- required for dry engine motoring
NORM - FADEC activates ignition during engine starts (ground or flight starts)
- FADEC commands both ignitors on during flameout and surge accommodation
ENGINE START SWITCH LIGHT ( momentary action )

SELECT segment (amber)
- indicates start control circuitry of the selected engine has armed
PUSH - START segment (amber)
- indicates engine start has been initialized
ENGINE START SELECT Switch

(three-position toggle, spring-loaded to center, magnetically latched in No. 1 or No.
2 position)
1 - arms start control circuits for #1 engine
- observe SELECT (amber) in engine START switch light
2 - arms start control circuit for #2 engine
- observe SELECT (amber) in engine START switch light
SWITCH unlatches when engine NH reaches 50% on START.