FUEL SHUT-OFF VALVE CLOSED ADVISORY LIGHT (white)

- APU fuel shut-off valve closed
- APU shutdown, manually or automatically
FUEL SHUT-OFF VALVE OPEN ADVISORY LIGHT (green)

- APU fuel shut-off valve open
- PWR switch light pushed
- APU circuits armed for starting or fire test
FIRE ADVISORY LIGHT (red)

- APU fire detected
- after 7 seconds extinguishing agent automatically releases, and the amber BTL ARM light goes out
EXTG SWITCH LIGHT (guarded, alternate action)

EXTG segment (white)
- APU fire extinguisher bottle can be activated manually if BTL ARM light is on
PUSH - EXTG segment (out)
- APU fire bottle cannot be activated or has been set off
BOTTLE LOW LIGHT (amber)

- fire extinguisher bottle is low or empty
FAULT ADVISORY LIGHT (amber)

- fault in the APU fire extinguisher system
- fault in the APU FPP