PWR SWITCH LIGHT ( alternate action )

PUSH - arms APU start circuits and opens the APU fuel valve, APU FUEL VALVE OPEN
light (green) shown on the APU fire protection panel.
- only arms if airplane on ground, no fire detected, and EXTG switch not selected
RUN segment (green)
- APU is at operating speed after the START switch light is pushed.
PUSH - RUN segment (out)
- closes APU fuel valve, APU FUEL VALVE CLOSED light (white) shown on the APU fire protection panel, and the APU stops
FAIL - a failure is detected and the APU automatically stops.
START SWITCH LIGHT ( alternate action )

PUSH - STARTER segment (amber)
- starts automatic APU start sequence
STARTER segment (out)
- APU start sequence complete or stopped
GEN SWITCH LIGHT (alternate action)

PUSH - ON segment (green)
- APU starter-generator is supplying DC power
PUSH - ON segment (out)
- selects APU generator offline
WARN segment (amber)
- APU starter-generator offline with APU running
BL AIR SWITCH LIGHT ( alternate action )

PUSH - OPEN segment (green)
- APU bleed air valve open
- APU bleed air supplies air to the ECS if engine bleed air is off
PUSH - OPEN segment (out)
- APU bleed air valve is closed
- selects APU bleed air off
GEN OHT ADVISORY LIGHT

GEN OHT segment (amber)
APU starter-generator overheat condition
APU automatically shuts down