RECIRC SWITCH (two-position)

- aft selection turns recirculation fan off
RECIRC - turns the fan on at high speed. ECU automatically selects slow speed when required
- the fan operates at slow speed only during single pack operation (and at start-up)
DUCTS TEMP GAUGE

- displays temperatures when selected by GAUGE selector in the:
- CABIN DUCT (supply) temperature
- CABIN temperature
- FLIGHT DECK DUCT (supply) temperature
GAUGE SELECTOR (rotary action)

- selects temperatures for display on the DUCT TEMP gauge:
- CABIN DUCT (supply) temperature
- CABIN temperature
- FLIGHT DECK (FC) DUCT (supply) temperature
PACKS CONTROL SWITCHES (three-position)

OFF - shuts related ACM off
MAN, AUTO
For both MAN and AUTO positions:
- modulates the pack Flow Control and Shut Off Valve
- packs start operating and supply conditioned air to the cabin and flight deck
- modulates the Pack Bypass Valve
- In accordance with the temp selections from the cockpit.
BLEED SWITCHES (two-position)

1 AND/OR 2 - starts bleed airflow from the No.1 and/or No.2 engines to the air conditioning
packs.
OFF - stops bleed airflow from the selected engine
BLEED CONTROL SELECTOR (rotary action)

- signals ECU to modulate the nacelle shut off valves
- provides airflow for one of three selected settings (for engine bleed operation)
MIN - for minimum bleed airflow
NORM - for moderate bleed airflow
MAX - for maximum bleed airflow